; This is teckit configuration file ; For options please refer to documentation https://xdevs.com/guide/teckit [teckit] if_debug = false ; (if true run all code w/o talking to real hardware) no_delays = false ; (don't use delays in code to run during debug) env_sensor = bme280 ; none or bme280 - Environment sensor ;if_debug = true ; (if true run all code w/o talking to real hardware) ;no_delays = true ; (don't use delays in code to run during debug) ;env_sensor = none ; none or bme280 - Environment sensor verbose = true ; verbose outputs in terminal interface = vxi ; (use linux-gpib bidning to run) vxi_ip = 192.168.1.2 ; # Main interface VXI IP dcc_ip = 192.168.1.10 ; tec_ip = 192.168.1.2 ; # K2510 VXI IP bus trm_ip = 192.168.1.2 ; # Thermometer VXI IP bus vxib_ip = 192.168.1.12 ; # Secondary interface VXI IP mfc_ip = 192.168.1.10 ; # Secondary interface VXI IP mfcb_ip = 192.168.1.10 ; # Secondary interface VXI IP dvxi_ip = 192.168.1.2 ; # Datron interface VXI IP em_ip = 192.168.1.13 ; # Electrometer VXI IP env_1620_ip = 192.168.1.7 ; Fluke 1620 LAN IP env_1620_port = 10001 ; Fluke 1620 port data_file = ../teckit/mil6010bx_test10_tcr_rx_fsl935_734abox_10k_rs_mg9330_1k_316uA_feb2022.dsv data2_file = ../teckit/nf742a_1281F1r_10ma_5720h1_Bsl935_A-5450precal_sep2020.dsv [acv_xfer] mode = f7922a ; Use Fluke 792A transfer unit 'f792a for 792A' detector = hp3458a ; Use HP3458A for digitize source = f5720a ; Use Fluke 5720A MFC as source range = 2.2 ; Used range on 792A transfer unit mfc_booster = 0 ; Boosted high voltage range if 1 [testset] mode = de4lta4 ; Execute resistance delta measurement if delta3 or delta4 (H1-2182A), dsb_v for DSB-nV all_test_disable = false ; Run bogus data if true sv_start = 17 ; Chamber start temperature sv_end = 17 ; Chamber end temperature peak_temp = 3329 ; Top soak temperature delay_start = 0 ; Delay before any operation start, seconds slope = 8 ; Hours, Time for slope (symmetric positive/negative) ramp time_start = 2 ; Hours, Initial hold temperature time, before positive slope starts time_dwell = 1 ; Hours, Dwell temperature duration time at peak-start/2 temperatures time_hold = 1 ; Hours, Hold temperature duration time once reached peak_temp time_end = 1 ; Hours, Final temperature duration once rampdown finished slope_shape = lymex_step ; Advanced shape type, lymex_step = soak time_start in middle of the ramps dcc_ix = 0.000316 ; DCC current for 6010B, in A delta_ipos = 100e-3 ; Positive step current, A delta_ineg = -100e-3 ; Negative step current, A dsb_vpos = 2.0 ; Positive step voltage, V dsb_vneg = 1.9997038 ; Negative step voltage, V testname = Fluke 732BX test and Fluke SL935, direct measurement ; testdut = xDevs.com KS3458ABCD, F8508 ; testnotes = NPLC100, DCV 10V for 3458s, TrueOhm RESL8 for F8508 ; [mode] run_selftest = false ; true to Run self-diag tests before perf-test) run_acal = false ; true to Run 3458 ACAL before perf-test) run_acal_dcv = false ; true to Run 3458 ACAL for DCV only before perf-test no_thermal = true ; set to true if you don't need TEC control, datalogging mode only [dmm] readtemp_period = 20 ; Query TEMP? reading every Nth sample [dut] reference1 = 10.0003940 reference2 = 1.00006304 reference3 = 1 reference4 = 1 reference5 = 10.0003940 reference6 = 10 reference7 = 10 reference8 = 9999.9739 [pid] kp = 180.0 ki = 0.020 kd = 9.500 [standard] mfc_gpib_addr = 1 ; GPIB Address mfc = f5700a ; (MFC type) mfc_acal = true ;(Run Calcheck + reports prior to DUT perf-test) [chatbot] irc_bot_enabled = false ; Activate IRC-chat bot for reporting/realtime log irc_server = xdevs.com ; irc_channel = TECkit ; irc_nick = TECkit ; irc_passwd = teckit_passwd ;